DN-6862:C1 • 8/1/2011 — Page 1 of 4
ACS Series Annunciators
ONYX
®
Series
ACM/AEM-24AT, ACM/AEM-48A
DN-6862:C1 • D-95
Annunciator Control Systems
General
The ONYX® Series ACS Annunciators provide a modular line
of products for annunciation and control of the NOTIFIER
ONYX® Series Intelligent Fire Alarm Control Panels, Network
Control Annunciators, and NOTIFIER’s legacy addressable
panels. The ACS line provides arrays of LEDs to indicate point
status and, in some versions, switches to control the state of
output circuits. These ACS units use a serial interface and may
be located at distances of up to 6,000 feet (1,828.8 meters)
from the panel.
Features
Speaker control mode for use with XPIQ and the following
panels: NFS2-3030, NFS2-640, NFS-320(C) and NFS-
320SYS. Enables the ACS to control operation of groups of
multi-channels mapped to groups of multi-speakers.
Compatible with existing annunciators.
Color-programmable LEDs.
On-board end-of-line resistors can be enabled/disabled by
setting a switch.
Alarm/Circuit On and Trouble LED per-point thxoption or
more dense Alarm-only option.
Touch-pad control switch option for remote control of sys-
tem relays; or silence, reset, and evacuate.
LEDs may be programmed to display status of indicating
circuits or control relays as well as system status condi-
tions.
System Trouble LED indicator.
On-Line/Power LED indicator.
Alarm and trouble resound with flash of new conditions.
Local sounder for both alarm and trouble conditions with
silence/acknowledge button (program options).
May be powered by 24 VDC from the panel or by remote
power supplies.
Microprocessor-controlled electronics, fully supervised.
Slip-in custom labels, lettered with standard typewriter or
LabelEase program.
Plug-in terminal blocks for ease of installation and service.
Construction
The ACS modules are provided in two basic controller mod-
ules, each with its expander module. The ACM-24AT provides
24 annunciation and control points per module, each with a
red, green, or yellow Alarm/Circuit On LED, a yellow Trouble
LED, and a touch-key switch. The ACM-48A provides 48
annunciation points per module, each with a red, green, or yel-
low Alarm/Circuit On LED (for annunciating control relays, the
LED indicates ON/OFF).
On the ACM-24AT, each LED point is individually color-pro-
grammable. On ACM-48A, each column of 24 LED points can
be color-configured using a DIP switch.
Temperature and humidity ranges: This system meets
NFPA requirements for operation at 0°C to 49°C (32°F to
120°F); and at a relative humidity (noncondensing) of 85% at
30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ±
1.1°F) per ULC. However, the useful life of the system’s
standby batteries and the electronic components may be
adversely affected by extreme temperature ranges and humid-
ity. Therefore, it is recommended that this system and all
peripherals be installed in an environment with a nominal room
temperature of 15°C to 27°C (60°F to 80°F).
Installation
The ACS Series annunciator and control subsystems use
modular hardware assemblies which allow the custom configu-
ration of the annunciator panel to fit the individual job require-
ments.
Standard backboxes and mounting hardware schemes, includ-
ing special remote cabinets, allow the annunciators to be con-
structed and configured with other system components.
When used with the NFS2-3030, NFS2-640, NFS-320 or leg-
acy panels, the ACS modules can be used for manual selec-
tion of speaker and telephone circuits. In this application, they
are typically mounted in the main control near the microphone
and telephone handset.
For remote annunciation applications, the modules are typi-
cally mounted in special ABF or ABS boxes. Control switch key
locks (AKS-1B) are available.
Communication between the ACS Series annunciators and the
host Fire Alarm Control Panel is made through an EIA-485
multi-drop loop, eliminating the need for costly wiring
schemes. Four wires are required, two for the EIA-485 com-
munications (twisted pair), and two for 24 VDC regulated
power.
Retrofit of ACS Series annunciators into existing systems is
easily accomplished. Software may require upgrading, and
some legacy panels may require an interface board.
All field-wiring terminations use removable, compression-type
terminal blocks for ease of installation, wiring, and circuit test-
ing.
ACM/AEM-24AT
ACM/AEM-48A
6862at24.wmf
6862a48.wmf
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - ACS Series Annunciators

DN-6862:C1 • 8/1/2011 — Page 1 of 4ACS Series AnnunciatorsONYX® Series ACM/AEM-24AT, ACM/AEM-48ADN-6862:C1 • D-95Annunciator Control SystemsGeneralThe

Seite 2 - Product Line Information

Page 2 of 4 — DN-6862:C1 • 8/1/2011OperationThe ACS Series annunciator and control system provides theNOTIFIER system with up to 32 remote serially co

Seite 3 - Agency Listings and Approvals

DN-6862:C1 • 8/1/2011 — Page 3 of 4wide] and an annunciator label. 9.938" (25.24 cm) high x17.75" (45.09 cm) wide x 2.5" (6.35 cm) deep

Seite 4

Page 4 of 4 — DN-6862:C1 • 8/1/2011ONYX® and NOTIFIER® are registered trademarks of Honeywell Interna-tional Inc. ©2011 by Honeywell International Inc